The COMPASS
Users Manual
Compliance Assurance
System
Emissions Inventory Module
"COMPASS-EI"
Process Data Control Corporation
Copyright PDC Corp. All Rights Reserved
Zobrazit stránku 0
1 2 3 4 5 6 ... 61 62

Shrnutí obsahu

Strany 1 - "COMPASS-EI"

The COMPASS User’s Manual Compliance Assurance System Emissions Inventory Module "COMPASS-EI" Process Data C

Strany 2 - TABLE OF CONTENTS

COMPASS-EI–Manual – Chapter 1 Page 7 Figure 1.4 Steps to Import TCEQ download file: 1. Browse the TCEQ download file (.TXT) file and click on

Strany 3

COMPASS-EI–Manual – Chapter 2 Page 8 CHAPTER 2: SETTING UP ENTITIES IN EI 2.1 The Command and Control Screen Navigation The design of EI is uniqu

Strany 4

COMPASS-EI–Manual – Chapter 2 Page 9 screen to add items. If an item on the C&C screen was double-clicked prior to the appearance of the List

Strany 5

COMPASS-EI–Manual – Chapter 2 Page 10 Users can enter comments in any Detail screen in the program in by clicking in the Comments text window, ent

Strany 6

COMPASS-EI–Manual – Chapter 2 Page 11 Figure 2.5 The C&C screen was designed to facilitate quality assurance of EI data without the need to

Strany 7

COMPASS-EI–Manual – Chapter 2 Page 12 Equipment Status Filter are in the upper right corner of the screen. The top central portion of the screen h

Strany 8

COMPASS-EI–Manual – Chapter 2 Page 13 account is automatically selected when you begin. If you wish to edit a different account, click on the desi

Strany 9

COMPASS-EI–Manual – Chapter 2 Page 14 devices that are associated with the selected Source ID. Double clicking in the gray area of a window brings

Strany 10

COMPASS-EI–Manual – Chapter 2 Page 15 Figure 2.7 As indicated in the lower-left portion of the CINs Detail screen, shown in Figure 2.7, EI also

Strany 11

COMPASS-EI–Manual – Chapter 2 Page 16 Figure 2.8 Equipment relationships involving control devices are entered in the Equipment Relationships sc

Strany 12

COMPASS-EI TABLE OF CONTENTS CHAPTER PAGE 1: INTRODUCTION ...

Strany 13

COMPASS-EI–Manual – Chapter 2 Page 17 Figure 2.9 2.5 Activities and Materials A list of Activities and Materials that pertains to the highlight

Strany 14 - RETURN button

COMPASS-EI–Manual – Chapter 2 Page 18 2. The Emissions window provides a means of displaying, adding and editing emissions by contaminant name an

Strany 15

COMPASS-EI–Manual – Chapter 4 Page 19 CHAPTER 3: EMISSION INVENTORY 3.1 EI Questionnaire There are twenty-two major sections in the EI Questionnai

Strany 16

COMPASS-EI–Manual – Chapter 4 Page 20 4. EPA Account #. The EPA assigned account number for the facility. 5. Owner / Operator Type. Is the owne

Strany 17

COMPASS-EI–Manual – Chapter 4 Page 21 17. County Name (Mandatory). The name of the county in which the specific plant/operating site resides. 18

Strany 18

COMPASS-EI–Manual – Chapter 4 Page 22 30. Inspection Fee. Represents the fee that the owner or operator of each account should pay to the commiss

Strany 19

COMPASS-EI–Manual – Chapter 4 Page 23 PLTSUPER – Plant Superintendent PLTCONTACT – Plant Contact PRODMGR – Production Manager REGSPEC – Regulato

Strany 20

COMPASS-EI–Manual – Chapter 4 Page 24 2. Address 2. The second line of the address, this field could contain a PO BOX (if both a street and PO B

Strany 21

COMPASS-EI–Manual – Chapter 4 Page 25 4. Plant Process Unit. The name used to identify a unique process operation. A process may include several

Strany 22

COMPASS-EI–Manual – Chapter 4 Page 26 11. Equipment Type (Mandatory). Represents the equipment type to which the FIN belongs. This field must be p

Strany 23

COMPASS-EI 3.10 Emissions... 36 3.11 Control Device Information

Strany 24

COMPASS-EI–Manual – Chapter 4 Page 27  Horizontal Fixed Roof Tank  Other Tank b.) Diameter. The tank diameter in feet. c.) Location. The lo

Strany 25 - Ms., Dr., etc.)

COMPASS-EI–Manual – Chapter 4 Page 28 m.) Control Pressure. The breather vent pressure setting. (psia) n.) Primary Seal.  Mechanical Shoe  Vapo

Strany 26

COMPASS-EI–Manual – Chapter 4 Page 29 b.) Firing Type. Describes the burner type.  Tangential  Opposed  Front  Other  Internal c.) Design C

Strany 27

COMPASS-EI–Manual – Chapter 4 Page 30 d.) Flow Model. Flow model describes whether the facility receives wastewater for ultimate disposal (“Dispos

Strany 28

COMPASS-EI–Manual – Chapter 4 Page 31 20. Equipment Leak Fugitives Information (Mandatory). Equipment Type: Equipment Leak Fugitives a.) % VOC I

Strany 29

COMPASS-EI–Manual – Chapter 4 Page 32 2. Agency ID Number. The ID number currently in use by the agency, which may differ from the user’s ID numb

Strany 30

COMPASS-EI–Manual – Chapter 4 Page 33 3.6 Stack Data (Mandatory) 1. Diameter. The inside diameter, in feet, for those emission points designated

Strany 31

COMPASS-EI–Manual – Chapter 4 Page 34 5. Lower Heat Value (BTU/SCF) The average lowest heating value of combustion, in BTU per standard cubic fee

Strany 32

COMPASS-EI–Manual – Chapter 4 Page 35 2. Material Pick the material associated with the Source ID from the drop down. 3. Activity Pick the acti

Strany 33

COMPASS-EI–Manual – Chapter 4 Page 36 3.10 Emissions Emissions are the types and quantities of air contaminants released from EPNs. Emissions ar

Strany 34

COMPASS-EI–Manual – Chapter 1 Page 1 CHAPTER 1: INTRODUCTION TO COMPASS-EI 1.1 About COMPASS-EI COMPASS-EI (“WinCeis”) is an emission inventory d

Strany 35

COMPASS-EI–Manual – Chapter 4 Page 37 9. Annual Upset + Maint Emissions (TONS/YEAR). The total annual upset and maintenance emissions during the

Strany 36

COMPASS-EI–Manual – Chapter 4 Page 38 16. Created On, Piped On and Modified On. These data elements represent the emission add or change date info

Strany 37

COMPASS-EI–Manual – Chapter 4 Page 39 Percent Control Efficiency: 9. VOC (Volatile Organic Compounds). Represents the CIN’s efficiency for contr

Strany 38

COMPASS-EI–Manual – Chapter 4 Page 40 22. Pct Time Off-Line (Mandatory). Represents the percentage of total annual operation time during which the

Strany 39

COMPASS-EI–Manual – Chapter 4 Page 41 CHAPTER 4: CONTAMINANT MAINTENANCE 4.1 About Contaminant Maintenance Contaminant Maintenance is accessed b

Strany 40

COMPASS-EI–Manual – Chapter 4 Page 42 Figure 4.1 The temperature adjustment factor will be applied only for emissions fr

Strany 41

COMPASS-EI–Manual – Chapter 4 Page 43 hidden. Users can filter the contaminants list by making the selection from the Active–All radio button on t

Strany 42

COMPASS-EI–Manual – Chapter 5 Page 44 CHAPTER 5: EQUIPMENT RELATIONSHIPS 5.1 About Equipment Relationships Equipment Relationships provide infor

Strany 43

COMPASS-EI–Manual – Chapter 5 Page 45 Figure 5.2 The first three columns show the Emission Source ID (“FIN” in Texas), Emission Point Number (“E

Strany 44

COMPASS-EI–Manual – Chapter 5 Page 46 definition, 100%. The percent flow for all equipment relationships that are connected in parallel is less th

Strany 45

COMPASS-EI–Manual – Chapter 1 Page 2 emission fee calculations. This analysis can now be executed with a single action, site-wide, in COMPASS-EI,

Strany 46

COMPASS-EI–Manual – Chapter 5 Page 47 NY–Equipment Relationships A customized Block Flow diagram that PDC developed for New York can also be pr

Strany 47

COMPASS-EI–Manual – Chapter 6 Page 48 CHAPTER 6: EMISSIONS/MATERIALS MAINTENANCE, UTILITIES, AND AGENCY EXPORT 6.1 Emission Maintenance – Global

Strany 48

COMPASS-EI–Manual – Chapter 6 Page 49 not be changed, but they will be balanced in such a way that all PM10 is accounted for in the TSP contaminan

Strany 49

COMPASS-EI–Manual – Chapter 6 Page 50 There are two functions that can change data: 1. Create/Edit uncontrolled emissions; and 2. Adjust annua

Strany 50

COMPASS-EI–Manual – Chapter 6 Page 51 2. Import Emissions is used to copy emission values from an external file that has been formatted in accord

Strany 51 - AGENCY EXPORT

COMPASS-EI–Manual – Chapter 6 Page 52 handles” were created in CONFIG.SYS (i.e., at least 60), and the drive/directory information has been entere

Strany 52

COMPASS-EI–Manual – Chapter 6 Page 53 c. Import the Upload File to Create Submittal Account for Archival saves the submittal file data in EI for

Strany 53

COMPASS-EI–Manual – Chapter 6 Page 54 Figure 6.4 The New York Emission Inventory report form includes a narrative description of the Process. Us

Strany 54

COMPASS-EI–Manual – Chapter 7 Page 55 CHAPTER 7: EI REPORTS 7.1 Emission Reports The Emission Reports menu item is located at the top of the COM

Strany 55

COMPASS-EI–Manual – Chapter 7 Page 56 shows any Permit Numbers for which emissions are found for the selected year, and the next shows any Process

Strany 56

COMPASS-EI–Manual – Chapter 1 Page 3 1.4 Installation Instructions Directions for the installation are furnished in a separate document entitled “

Strany 57

COMPASS-EI–Manual – Chapter 7 Page 57 Users can select the next action from command buttons located at the top of the screen. The Retrieve Filter

Strany 58 - CHAPTER 7: EI REPORTS

COMPASS-EI–Manual – Chapter 7 Page 58 7.1.3 SARA Emissions Emissions of SARA-flagged chemicals (See Section 4.1: Contaminant Maintenance for more

Strany 59

COMPASS-EI–Manual – Chapter 7 Page 59 7.1.5 Emissions with FIN and EPN Status This report shows emissions by their associated Source and Point,

Strany 60

COMPASS-EI–Manual – Chapter 1 Page 4 1.8 Importing Emission Inventory Data and Logging Into EI Users will be asked to enter their User ID and Pas

Strany 61

COMPASS-EI–Manual – Chapter 1 Page 5 Figure 1.2 Please note that the user needs to use the COMPASS Utilities module for importing a TCEQ downlo

Strany 62

COMPASS-EI–Manual – Chapter 1 Page 6 Figure 1.3 To import the TCEQ download file, click on the Acct Import button, and the data import screen

Komentáře k této Příručce

Žádné komentáře